Philips M1194A SpO₂ sensor measures perfusion at the ear for consistent SpO₂ data even in surgical and low-perfusion patients. It clips gently yet securely to the ear lobe and is suitable for patients weighing more than 40 kg (88 lbs).

Features
For low-perfusion patients

Consistently measures SpO2 in low-perfusion patients

For patients in low-perfusion states such as severe shock, septicemia, hypovolemia, vasoconstriction and peripheral vascular disease, it is beneficial to measure oxygenation at a central site, such as the earlobe. The earlobe is easily accessible, features small vasculature, and provides a quick response rate. The M1194A is also well-suited for surgical patients, because the finger is often inaccessible during surgery.
Reduces signal interference

Designed for FAST-SpO₂

Our pulse oximetry sensors are designed specifically for Philips proprietary FAST-SpO₂ (Fourier Artifact Suppression Technology) algorithm. Together, they reduce effects from patient movement, electronic interference, ambient light and low perfusion.
  • For low-perfusion patients
  • Reduces signal interference
See all features
For low-perfusion patients

Consistently measures SpO2 in low-perfusion patients

For patients in low-perfusion states such as severe shock, septicemia, hypovolemia, vasoconstriction and peripheral vascular disease, it is beneficial to measure oxygenation at a central site, such as the earlobe. The earlobe is easily accessible, features small vasculature, and provides a quick response rate. The M1194A is also well-suited for surgical patients, because the finger is often inaccessible during surgery.
Reduces signal interference

Designed for FAST-SpO₂

Our pulse oximetry sensors are designed specifically for Philips proprietary FAST-SpO₂ (Fourier Artifact Suppression Technology) algorithm. Together, they reduce effects from patient movement, electronic interference, ambient light and low perfusion.

Specifications

Product details
Product details
CE Certified
  • Yes
Product Type
  • Sensor
Not manufactured with natural rubber latex
  • Yes
Use with Non-Philips Healthcare Equipment
  • No
Packaging Unit
  • 1 sensor
Minimum Shelf Life
  • None
Product Category
  • SpO2
Sterile OR Non-Sterile
  • Non-Sterile
Package Weight
  • .240 kg
Single-Patient Use OR Multi-Patient Use
  • Multi-Patient Use
Use with Philips Healthcare Equipment
  • 862108, 862231, 862439, 862474, 862478, 863063, 863064, 863065, 863066, 863068, 863071, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, M1020A, M1020B, M1350B, M1350C, M2600A, M2703A, M2705A, M3000A, M3001A, M3002A, M3535A, M3536A, M3536M, M4735A, M8102A, M8105A, M8105AT, M8105AS
SpO2 Sensor
SpO2 Sensor
Recommended Patient Weight
  • <gt/>40 kg (<gt/>88 lb)
Application Site
  • Ear
Adapter Cable Compatibility
  • M1941A
Patient Application
  • Child; Adult
Cable Length
  • 1.5 m (4.9')
Product details
Product details
CE Certified
  • Yes
Product Type
  • Sensor
SpO2 Sensor
SpO2 Sensor
Recommended Patient Weight
  • <gt/>40 kg (<gt/>88 lb)
Application Site
  • Ear
See all specifications
Product details
Product details
CE Certified
  • Yes
Product Type
  • Sensor
Not manufactured with natural rubber latex
  • Yes
Use with Non-Philips Healthcare Equipment
  • No
Packaging Unit
  • 1 sensor
Minimum Shelf Life
  • None
Product Category
  • SpO2
Sterile OR Non-Sterile
  • Non-Sterile
Package Weight
  • .240 kg
Single-Patient Use OR Multi-Patient Use
  • Multi-Patient Use
Use with Philips Healthcare Equipment
  • 862108, 862231, 862439, 862474, 862478, 863063, 863064, 863065, 863066, 863068, 863071, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, M1020A, M1020B, M1350B, M1350C, M2600A, M2703A, M2705A, M3000A, M3001A, M3002A, M3535A, M3536A, M3536M, M4735A, M8102A, M8105A, M8105AT, M8105AS
SpO2 Sensor
SpO2 Sensor
Recommended Patient Weight
  • <gt/>40 kg (<gt/>88 lb)
Application Site
  • Ear
Adapter Cable Compatibility
  • M1941A
Patient Application
  • Child; Adult
Cable Length
  • 1.5 m (4.9')